Climate Series 7000i features

The Matter certificate of this Room Air Conditioner and the clusters its device type includes. Back to the product page

DCL Verified
  • Matter 1.2
  • Wi-Fi

Summary

Matter certification

Certificate
CSA2447DMAT43824-24
Certified on
27 August 2024
Specification version
Matter 1.2
Transport
wi-fi
Software version
2.0.0 (latest)

Software versions

VersionCertifiedCertificate
2.0.0Latest27 August 2024CSA2447DMAT43824-24
1.1.0Not certified

Clusters in this device type

11 clusters in 5 groups, from the Room Air Conditioner device type. Server means a device offers the cluster; client means it can use the cluster on another device. Mandatory, optional and conditional describe the device type, not this product.

Controls (4)

  • Fan Control0x0202Server, optional
    included in this device type, not confirmed supported
  • On/Off0x0006Server, mandatory
    included in this device type, not confirmed supported
  • Thermostat0x0201Server, mandatory
    included in this device type, not confirmed supported
  • included in this device type, not confirmed supported

Sensors (2)

Automation and scenes (2)

  • Groups0x0004Server, optional
    included in this device type, not confirmed supported
  • Scenes Management0x0062Server, optional
    included in this device type, not confirmed supported

Appliances (2)

Other (1)

  • Identify0x0003Server, mandatory
    included in this device type, not confirmed supported

Advanced

The features each of those clusters defines in the Matter specification. A feature is an optional part of a cluster, such as dimming for an on and off switch. These are the features the cluster has, not the ones this product has: the ledger does not say which a product implements, and HausMesh does not guess.

Fan Control

0x0202
included in this device type, not confirmed supportedControls. Server, optional. About this cluster
Features of the Fan Control cluster
FeatureCodeBitWhat it is
MultiSpeedSPD00-SpeedMax Fan Speeds
AutoAUT1Automatic mode supported for fan speed
RockingRCK2Rocking movement supported
WindWND3Wind emulation supported
StepSTEP4Step command supported
AirflowDirectionDIR5Airflow Direction attribute is supported

On/Off

0x0006
included in this device type, not confirmed supportedControls. Server, mandatory. About this cluster
Features of the On/Off cluster
FeatureCodeBitWhat it is
LightingLT0Behavior that supports lighting applications.
DeadFrontBehaviorDF1Device has Dead Front behavior
OffOnlyOFFONLY2Device supports the OffOnly Feature feature

Thermostat

0x0201
included in this device type, not confirmed supportedControls. Server, mandatory. About this cluster
Features of the Thermostat cluster
FeatureCodeBitWhat it is
HeatingHEAT0Thermostat is capable of managing a heating device
CoolingCOOL1Thermostat is capable of managing a cooling device
OccupancyOCC2Supports Occupied and Unoccupied setpoints
ScheduleConfigurationSCH3Supports remote configuration of a weekly schedule of setpoint transitions
SetbackSB4
AutoModeAUTO5Supports a System Mode of Auto
LocalTemperatureNotExposedLTNE6Thermostat does not expose the LocalTemperature Value in the LocalTemperature attribute
MatterScheduleConfigurationMSCH7Supports enhanced schedules
PresetsPRES8Thermostat supports setpoint presets
EventsTEVT9Thermostat supports events
ThermostatSuggestionsTSUGGEST10Thermostat supports suggestions

Groups

0x0004
included in this device type, not confirmed supportedAutomation and scenes. Server, optional. About this cluster
Features of the Groups cluster
FeatureCodeBitWhat it is
GroupNamesGN0The ability to store a name for a group.

Scenes Management

0x0062
included in this device type, not confirmed supportedAutomation and scenes. Server, optional. About this cluster
Features of the Scenes Management cluster
FeatureCodeBitWhat it is
SceneNamesSN0The ability to store a name for a scene.

Activated Carbon Filter Monitoring

0x0072
included in this device type, not confirmed supportedAppliances. Server, optional. About this cluster
Features of the Activated Carbon Filter Monitoring cluster
FeatureCodeBitWhat it is
ConditionCON0Supports monitoring the condition of the resource in percentage
WarningWRN1Supports warning indication
ReplacementProductListREP2Supports specifying the list of replacement products

HEPA Filter Monitoring

0x0071
included in this device type, not confirmed supportedAppliances. Server, optional. About this cluster
Features of the HEPA Filter Monitoring cluster
FeatureCodeBitWhat it is
ConditionCON0Supports monitoring the condition of the resource in percentage
WarningWRN1Supports warning indication
ReplacementProductListREP2Supports specifying the list of replacement products

Clusters that define no features: Thermostat User Interface Configuration, Relative Humidity Measurement, Temperature Measurement, Identify.