LG Air Quality Sensor features

The Matter certificate of this Air Quality Sensor and the clusters its device type includes. Back to the product page

DCL Verified
  • Matter 1.2
  • Thread
  • Bluetooth

Summary

Matter certification

Certificate
CSA26561MAT56105-24
Certified on
17 October 2026
Specification version
Matter 1.2
Transport
thread,bluetooth
Software version
1.3.00 (latest)

Software versions

VersionCertifiedCertificate
1.3.00Latest17 October 2026CSA26561MAT56105-24
1.2.002 November 2025CSA25D2AMAT48252-24
1.1.0013 February 2025CSA250E6MAT45112-24
1.0.0713 September 2024CSA24508MAT43963-24

Clusters in this device type

14 clusters in 2 groups, from the Air Quality Sensor device type. Server means a device offers the cluster; client means it can use the cluster on another device. Mandatory, optional and conditional describe the device type, not this product.

Sensors (13)

Other (1)

  • Identify0x0003Server, mandatory
    included in this device type, not confirmed supported

Advanced

The features each of those clusters defines in the Matter specification. A feature is an optional part of a cluster, such as dimming for an on and off switch. These are the features the cluster has, not the ones this product has: the ledger does not say which a product implements, and HausMesh does not guess.

Air Quality

0x005B
included in this device type, not confirmed supportedSensors. Server, mandatory. About this cluster
Features of the Air Quality cluster
FeatureCodeBitWhat it is
FairFAIR0Cluster supports the Fair air quality level
ModerateMOD1Cluster supports the Moderate air quality level
VeryPoorVPOOR2Cluster supports the Very poor air quality level
ExtremelyPoorXPOOR3Cluster supports the Extremely poor air quality level

Carbon Dioxide Concentration Measurement

0x040D
included in this device type, not confirmed supportedSensors. Server, optional. About this cluster
Features of the Carbon Dioxide Concentration Measurement cluster
FeatureCodeBitWhat it is
NumericMeasurementMEA0Cluster supports numeric measurement of substance
LevelIndicationLEV1Cluster supports basic level indication for substance using the ConcentrationLevel enum
MediumLevelMED2Cluster supports the Medium Concentration Level
CriticalLevelCRI3Cluster supports the Critical Concentration Level
PeakMeasurementPEA4Cluster supports peak numeric measurement of substance
AverageMeasurementAVG5Cluster supports average numeric measurement of substance

Carbon Monoxide Concentration Measurement

0x040C
included in this device type, not confirmed supportedSensors. Server, optional. About this cluster
Features of the Carbon Monoxide Concentration Measurement cluster
FeatureCodeBitWhat it is
NumericMeasurementMEA0Cluster supports numeric measurement of substance
LevelIndicationLEV1Cluster supports basic level indication for substance using the ConcentrationLevel enum
MediumLevelMED2Cluster supports the Medium Concentration Level
CriticalLevelCRI3Cluster supports the Critical Concentration Level
PeakMeasurementPEA4Cluster supports peak numeric measurement of substance
AverageMeasurementAVG5Cluster supports average numeric measurement of substance

Formaldehyde Concentration Measurement

0x042B
included in this device type, not confirmed supportedSensors. Server, optional. About this cluster
Features of the Formaldehyde Concentration Measurement cluster
FeatureCodeBitWhat it is
NumericMeasurementMEA0Cluster supports numeric measurement of substance
LevelIndicationLEV1Cluster supports basic level indication for substance using the ConcentrationLevel enum
MediumLevelMED2Cluster supports the Medium Concentration Level
CriticalLevelCRI3Cluster supports the Critical Concentration Level
PeakMeasurementPEA4Cluster supports peak numeric measurement of substance
AverageMeasurementAVG5Cluster supports average numeric measurement of substance

Nitrogen Dioxide Concentration Measurement

0x0413
included in this device type, not confirmed supportedSensors. Server, optional. About this cluster
Features of the Nitrogen Dioxide Concentration Measurement cluster
FeatureCodeBitWhat it is
NumericMeasurementMEA0Cluster supports numeric measurement of substance
LevelIndicationLEV1Cluster supports basic level indication for substance using the ConcentrationLevel enum
MediumLevelMED2Cluster supports the Medium Concentration Level
CriticalLevelCRI3Cluster supports the Critical Concentration Level
PeakMeasurementPEA4Cluster supports peak numeric measurement of substance
AverageMeasurementAVG5Cluster supports average numeric measurement of substance

Ozone Concentration Measurement

0x0415
included in this device type, not confirmed supportedSensors. Server, optional. About this cluster
Features of the Ozone Concentration Measurement cluster
FeatureCodeBitWhat it is
NumericMeasurementMEA0Cluster supports numeric measurement of substance
LevelIndicationLEV1Cluster supports basic level indication for substance using the ConcentrationLevel enum
MediumLevelMED2Cluster supports the Medium Concentration Level
CriticalLevelCRI3Cluster supports the Critical Concentration Level
PeakMeasurementPEA4Cluster supports peak numeric measurement of substance
AverageMeasurementAVG5Cluster supports average numeric measurement of substance

PM1 Concentration Measurement

0x042C
included in this device type, not confirmed supportedSensors. Server, optional. About this cluster
Features of the PM1 Concentration Measurement cluster
FeatureCodeBitWhat it is
NumericMeasurementMEA0Cluster supports numeric measurement of substance
LevelIndicationLEV1Cluster supports basic level indication for substance using the ConcentrationLevel enum
MediumLevelMED2Cluster supports the Medium Concentration Level
CriticalLevelCRI3Cluster supports the Critical Concentration Level
PeakMeasurementPEA4Cluster supports peak numeric measurement of substance
AverageMeasurementAVG5Cluster supports average numeric measurement of substance

PM10 Concentration Measurement

0x042D
included in this device type, not confirmed supportedSensors. Server, optional. About this cluster
Features of the PM10 Concentration Measurement cluster
FeatureCodeBitWhat it is
NumericMeasurementMEA0Cluster supports numeric measurement of substance
LevelIndicationLEV1Cluster supports basic level indication for substance using the ConcentrationLevel enum
MediumLevelMED2Cluster supports the Medium Concentration Level
CriticalLevelCRI3Cluster supports the Critical Concentration Level
PeakMeasurementPEA4Cluster supports peak numeric measurement of substance
AverageMeasurementAVG5Cluster supports average numeric measurement of substance

PM2.5 Concentration Measurement

0x042A
included in this device type, not confirmed supportedSensors. Server, optional. About this cluster
Features of the PM2.5 Concentration Measurement cluster
FeatureCodeBitWhat it is
NumericMeasurementMEA0Cluster supports numeric measurement of substance
LevelIndicationLEV1Cluster supports basic level indication for substance using the ConcentrationLevel enum
MediumLevelMED2Cluster supports the Medium Concentration Level
CriticalLevelCRI3Cluster supports the Critical Concentration Level
PeakMeasurementPEA4Cluster supports peak numeric measurement of substance
AverageMeasurementAVG5Cluster supports average numeric measurement of substance

Radon Concentration Measurement

0x042F
included in this device type, not confirmed supportedSensors. Server, optional. About this cluster
Features of the Radon Concentration Measurement cluster
FeatureCodeBitWhat it is
NumericMeasurementMEA0Cluster supports numeric measurement of substance
LevelIndicationLEV1Cluster supports basic level indication for substance using the ConcentrationLevel enum
MediumLevelMED2Cluster supports the Medium Concentration Level
CriticalLevelCRI3Cluster supports the Critical Concentration Level
PeakMeasurementPEA4Cluster supports peak numeric measurement of substance
AverageMeasurementAVG5Cluster supports average numeric measurement of substance

Total Volatile Organic Compounds Concentration Measurement

0x042E
included in this device type, not confirmed supportedSensors. Server, optional. About this cluster
Features of the Total Volatile Organic Compounds Concentration Measurement cluster
FeatureCodeBitWhat it is
NumericMeasurementMEA0Cluster supports numeric measurement of substance
LevelIndicationLEV1Cluster supports basic level indication for substance using the ConcentrationLevel enum
MediumLevelMED2Cluster supports the Medium Concentration Level
CriticalLevelCRI3Cluster supports the Critical Concentration Level
PeakMeasurementPEA4Cluster supports peak numeric measurement of substance
AverageMeasurementAVG5Cluster supports average numeric measurement of substance

Clusters that define no features: Relative Humidity Measurement, Temperature Measurement, Identify.